羞羞答答xxdd影院欧美_97色伦色在线综合视频_亚洲巨乳在线_亚洲伊人久久大香线蕉苏妲己

BIOWEST西班牙瓊脂糖 Agarose G-10 100g(111860)

Biowest 相關資料如下 : 最權威的西班牙瓊脂糖(Biowest Agarose)是一種電泳級別純度很高的產品,作為著名的瓊脂糖品牌,具有極佳的產品性價比,在同行中有著非常高的知名度,在同類產品中占據著最高的市場份額,西班牙瓊脂糖(Biowest Agarose)不僅適用于蛋白電泳也可以用于其它核酸分析電泳。技術參數: Agarose Low EEO&

  • 品牌: BIOWEST
  • 型號: 111860
  • 其他型號:
Biowest 相關資料如下 : 
最權威的西班牙瓊脂糖(Biowest Agarose)是一種電泳級別純度很高的產品,作為著名的瓊脂糖品牌,具有極佳的產品性價比,在同行中有著非常高的知名度,在同類產品中占據著最高的市場份額,西班牙瓊脂糖(Biowest Agarose)不僅適用于蛋白電泳也可以用于其它核酸分析電泳。
技術參數: Agarose Low EEO 
Gel Strength (1.0%) (g/cm2 )………………≥750
Gelling Range (1.5%) (℃)………………36 - 39
Melting Range (℃)………………………87 - 89
EEO (-mr )……………………………………≤0.15
Sulfate (%)………………………………≤0.15
DNase……………………………………None Detected
RNase……………………………………None Detected
Protease………………………………None Detected
 
Introduction: 
Routine use agarose is ideal for everyday analysis of nucleic acids by gel electrophoresis or blotting (Northern or Southern) and is also suitable for protein applications such as Ouchterlony and radial immunodiffusion (RID).
Analysis Note  : 
Sulfate content - used as an indicator of purity, since sulfate is the major ionic group present.
Gel strength - the force that must be applied to a gel to cause it to fracture.
Gel point - the temperature at which an aqueous agarose solution forms a gel as it cools. Agarose solutions exhibit hysteresis in the liquid-to-gel transition - that is, their gel point is not the same as their melting temperature.
Electroendosmosis (EEO) - a movement of liquid through the gel. Anionic groups in an agarose gel are affixed to the matrix and cannot move, but dissociable counter cations can migrate toward the cathode in the matrix, giving rise to EEO. Since electrophoretic movement of biopolymers is usually toward the anode, EEO can disrupt separations because of internal convection.
 
Preparation  of  Agarose  Gels  for  DNA  separations: 
Weigh out the desired amount of agarose and place in an Erlenmeyer flask with a measured amount of electrophoresis buffer, e.g. for an 0.8% gel, add 0.8 gm of agarose and 100ml of TBE Buffer (1X), to a 200 ml flask. The larger flask insures against the agarose boiling over. Dissolve the agarose in a boiling water bath or in a revolving-plate microwave oven. All the grains of agarose should be dissolved and the solution clear. Cool the solution to 60°C (70°C for concentrations 2% or above) and pour immediately. Allow the gel to set for one-half hour before using. Make sure to use the same electrophoresis buffer in the gel as for the running buffer.